61MP Area Scan Camera, IMX455, 10GigE, color, F-mount, with TEC
> 25 MP 10GigE Area Scan Cameras — IMX455, Rolling shutter, CMOS, F-mount
Model
- Product Model
- MV-CH610-10TC-F-TF
- Type
- 61MP Area Scan Camera, IMX455, 10GigE, color, F-mount, with TEC
Performance
- Sensor type
- CMOS, rolling shutter
- Sensor model
- Sony® IMX455
- Pixel size
- 3.76 μm × 3.76 μm
- Sensor size
- 36 mm × 24 mm
- Sensor size (computed)from resolution × pixel pitch
- 35.98 × 23.99 mm
- Sensor diagonal
- 43.24 mm
- Resolution
- 9568 × 6380
- Max. frame rate
- 17.9 fps @ 9568 × 6380 Bayer RG 8
- Dynamic range
- 75.3 dB
- SNR
- 46.8 dB
- Gain
- 0 dB to 36 dB
- Exposure time
- 9 μs to 10 sec
- Exposure mode
- Off/Once/Continuous exposure mode, supports Global Reset
- Mono/color
- Color
- Pixel format
- Mono 8/10/12/16 Bayer RG 8/10/10Packed/12/12Packed/16 YUV422_8, YUV422_8_YUYV RGB 8, BGR 8
- Binning
- Supports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
- Decimation
- Supports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
- Reverse image
- Supports horizontal reverse image output
Electrical feature
- Data interface
- 10 Gigabit Ethernet (10000 Mbit/s), compatible with Gigabit Ethernet (1000 Mbit/s)
- Digital I/O
- 12-pin P10 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2), and RS-232 × 1.
- Power supply
- 24 VDC
- Power consumption
- Typ. 14.4 W @ 24 VDC (non-TEC mode) Typ. 27.6 W @ 24 VDC (TEC mode)
Mechanical
- Lens mount
- F-mount, flange back length 46.5 mm
- Dimension
- 100 mm × 100 mm × 82 mm (3.9" × 3.9" × 3.2")
- Weight
- Approx. 1090 g (2.4 lb.)
- Ingress protection
- IP40 (under proper lens installation and wiring)
- Temperature
- Working temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F)
- Humidity
- 20% RH to 95% RH (no condensation)
General
- Client software
- MVS or third-party software meeting with GigE Vision Protocol
- Operating system
- 32/64-bit Windows 7/10, 64-bit Windows 11, 32/64-bit Linux
- Compatibility
- GigE Vision V2.0, GenlCam
- Certification
- CE, RoHS, KC
Firmware
Choosing a lens
Choosing a lens
Solve for
Focal length
108 mm
Magnification: 0.36×
Resolution per pixel
0.0408 mm/px
Smallest detectable feature: 0.123 mm
The formula holds for standard (entocentric) lenses and assumes the working distance is much larger than the focal length. It does not apply to telecentric lenses, and it accounts for neither depth of field nor distortion.
Data cables the manufacturer lists
Frame grabbers
Lenses that fit this camera
Filtered by the F-mount thread and by coverage — the image circle is at least 43.24 mm, this sensor's diagonal. A smaller circle darkens the corners of every frame. Ask us to confirm