12MP Area Scan Camera, GMAX3412, 1-link CXP-12, C-mount, without fan, with heat sink, Mono
12–25 MP CoaXPress Area Scan Cameras — GMAX3412, Global shutter, CMOS, C-mount
Model
- Product Model
- MV-CH120-90Y1M-NH
- Type
- 12MP Area Scan Camera, GMAX3412, 1-link CXP-12, C-mount, without fan, with heat sink, Mono
Performance
- Sensor type
- CMOS, global shutter
- Sensor model
- Gpixel GMAX3412
- Pixel size
- 3.4 μm × 3.4 μm
- Sensor size
- 1.1"
- Sensor size (computed)from resolution × pixel pitch
- 13.93 × 10.44 mm
- Sensor diagonal
- 17.41 mm
- Resolution
- 4096 × 3072
- Max. frame rate
- 93.9 fps @ 4096 × 3072 Mono 8
- Dynamic range
- 59.7 dB
- SNR
- 39 dB
- Gain
- 0 dB to 6.1 dB
- Exposure time
- 6 μs to 10 sec
- Exposure mode
- Off/Once/Continuous exposure mode
- Mono/color
- Mono
- Pixel format
- Mono 8/10/12
- Binning
- Supports 1 × 1, 1 × 2, 1 × 4, 2 ×1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
- Decimation
- Supports 1 × 1, 1 × 2, 1 × 4, 2 ×1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
- Reverse image
- Supports horizontal and vertical reverse image output
Electrical feature
- Data interface
- CoaXPress with Micro-BNC interface
- Digital I/O
- 6-pin P7 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2)
- Power supply
- 12 VDC to 24 VDC, supports PoCXP
- Power consumption
- Typ. 5 W @ 12 VDC
Mechanical
- Lens mount
- C-mount
- Dimension
- Device with heat sink: 29 mm × 85 mm × 42 mm (1.1" × 3.3" × 1.7") Device without heat sink: 29 mm × 29 mm × 42 mm (1.1" × 1.1" × 1.7")
- Weight
- Device with heat sink: Approx. 170 g (0.4 lb.) Device without heat sink: Approx. 90 g (0.2 lb.)
- Ingress protection
- IP40 (under proper lens installation and wiring)
- Temperature
- Working temperature for device with heat sink: 0 °C to 50 °C (32 °F to 122 °F) Working temperature for device without heat sink: 0 °C to 40 °C (32 °F to 104 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F)
- Humidity
- 20% RH to 95% RH (no condensation)
General
- Client software
- MVS or third-party software meeting with CoaXPress Protocol
- Operating system
- 32/64-bit Windows 7/10, 64-bit Window 11, and 32/64-bit Linux
- Compatibility
- CoaXPress, GenlCam
- Certification
- CE, RoHS, KC
Firmware
Choosing a lens
Choosing a lens
Solve for
Focal length
41.8 mm
Magnification: 0.14×
Resolution per pixel
0.0408 mm/px
Smallest detectable feature: 0.123 mm
The formula holds for standard (entocentric) lenses and assumes the working distance is much larger than the focal length. It does not apply to telecentric lenses, and it accounts for neither depth of field nor distortion.
Data cables the manufacturer lists
Power and I/O cables
Frame grabbers
Lenses that fit this camera
Filtered by the C-mount thread and by coverage — the image circle is at least 17.41 mm, this sensor's diagonal. A smaller circle darkens the corners of every frame. Ask us to confirm

MVL-KF0618M-12MPE
6mm, F1.8, 1.1", 12MP Lens, C-Mount

MVL-KF0814M-12MPE
8mm, F1.4, 1.1", 12MP Lens, C-Mount

MVL-KF1224M-25MP
12mm, F2.4, 1.2", 25MP Lens, C-Mount

MVL-KF1228M-12MP
12mm, F2.8, 1.1", 12MP Lens, C-Mount

MVL-KF1228M-12MPE
12mm, F2.8, 1.1", 12MP Lens, C-Mount

SA1220M-10MP
12mm, F2.0, 4/3", 10MP Lens, C-Mount

MVL-KF1624M-25MP
16mm, F2.4, 1.2", 25MP Lens, C-Mount

MVL-KF1628M-12MP
16mm, F2.8, 1.1", 12MP Lens, C-Mount

MVL-KF1628M-12MPE
16mm, F2.8, 1.1", 12MP Lens, C-Mount

MVL-KF1640-25MP
16mm, Fixed Iris F4, 1.2", 25MP Lens, C-Mount

SA1620M-10MP
16mm, F2.0, 4/3", 10MP Lens, C-Mount

MVL-KF2524M-25MP