Skip to content

2–5 MP GigE Code Readers — 12 mm, Global shutter, CMOS, M12-mount

Model

Product Model
MV-ID5050XM-12M-RBN
Type
MV-ID5050XM-12M-RBN

Performance

Symbologies
1D codes: Code 39, Code 93, Code 128 (GS1-128 included), CodaBar, EAN 8, EAN 13, UPCA, UPCE, ITF 14, ITF 25, Matrix 25, MSI, China Post, Code 11, Industrial 2of5, and Pharmacode 2D matrix codes: QR Code (GS1-QR included), Data Matrix (GS1-DM included), MicroQR, AZTEC, HanXin 2D stacked codes: PDF417, MicroPDF417
Max. frame rate
92 fps
Max. reading speed
120 codes/sec
Sensor type
CMOS, global shutter
Pixel size
3.45 μm × 3.45 μm
Sensor size
1/1.45"
Sensor size (computed)from resolution × pixel pitch
8.39 × 7.07 mm
Sensor diagonal
10.97 mm
Resolution
2432 × 2048
Exposure time
38 μs to 3 ms
Gain
0 dB to 37 dB
Mono/color
Mono

Electrical feature

Data interface
Gigabit Ethernet (1000 Mbit/s)
Communication protocol
SmartSDK, TCP Client, TCP Server, Serial, FTP, Profinet, Ethernet/IP, MELSEC/SLMP, ModBus, Fins, UDP
Digital I/O
12-pin M12 connector provides power and I/O, including opto-isolated input (LineIn 0/1/2) × 3, opto-isolated output (LineOut 3/4/5) × 3, RS-232 input × 1, and RS-232 output × 1. Supports device triggering via pressing on touchscreen.
Power supply
24 ± 10% VDC
Power consumption
Avg.: 11 W @ 24 VDC (light source enabled) Max.: 36 W @ 24 VDC (light source enabled)

Mechanical

Focal length
12 mm
Lens mount
M12-mount, mechanical focus supported
Lens cap
Half polarization lens cap by default. Transparent and full polarization caps are optional.
Light source
Red light by default. White/blue/IR light is optional.
Indicator
Multi-directional device body indicator
Shell material
Metal
Dimension
Straight angle: 112.3 mm × 54 mm × 60.2 mm (4.4" × 2.1" × 2.4") Right angle: 88.7 mm × 54 mm × 82.5 mm (3.5" × 2.1" × 3.2")
Weight
Approx. 405 g (0.9 lb.)
Ingress protection
IP67 (under proper installation of waterproof lens cap)
Temperature
Working temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F)
Humidity
20% RH to 95% RH (no condensation)
Vibration resistance
Device only: 10 Hz to 55 Hz, 1.5 mm full amplitude, 2 hours per axis (X/Y/Z) (IEC 60068-2-6:2007\GB/T 2423.10-2019)
Shock resistance
Device only, 30 g / 11 ms, half-sine wave, 500 shocks per axis (6 directions) (IEC 60068-2-27\GB/T 2423.5-2019)

General

Client software
IDMVS
Certification
CE, RoHS, KC

Firmware

Choosing a lens

Choosing a lens

Solve for
Focal length
25.2 mm
Magnification: 0.084×
Resolution per pixel
0.0408 mm/px
Smallest detectable feature: 0.123 mm

The formula holds for standard (entocentric) lenses and assumes the working distance is much larger than the focal length. It does not apply to telecentric lenses, and it accounts for neither depth of field nor distortion.

Data cables that fit

Matched on connector and protocol from the manufacturer's catalogue — not its own recommendation list. Ask us to confirm