Skip to content

2MP Board Level Camera, USB3, Color, C-mount

MV-CB020-60UC-CHikrobotGlobal shutter

2–5 MP USB3 Area Scan Cameras — Global shutter, CMOS, C-mount

Model

Product Model
MV-CB020-60UC-C
Type
2MP Board Level Camera, USB3, Color, C-mount

Performance

Sensor type
CMOS, global shutter
Sensor model
Stacked BSI
Pixel format
Mono 8 Bayer GB 8/10/10Packed/12/12Packed, YUV422Packed, YUV422_YUYV_Packed, RGB 8, BGR 8
Pixel size
3.45 μm × 3.45 μm
Sensor size
1/2.53"
Sensor size (computed)from resolution × pixel pitch
5.6 × 4.28 mm
Sensor diagonal
7.05 mm
Resolution
1624 × 1240
Max. frame rate
179.9 fps @ 1624 × 1240 Bayer GB 8
Dynamic range
68.6 dB
SNR
44.1 dB
Gain
0 dB to 24 dB
Exposure time
23 μs to 10 sec
Exposure mode
Off/ Once/ Continuous exposure mode
Mono/color
Color
Binning
Supports 1 × 1, 2 × 2, 4 × 4
Decimation
Supports 1 × 1, 2 × 2, 4 × 4
Reverse image
Supports horizontal and vertical reverse image output

Electrical feature

Data interface
USB 3.0, compatible with USB 2.0
Digital I/O
Bi-directional non-isolated I/O × 2 (Line 2, Line 5)
Power supply
USB 3.0 power supply
Power consumption
Typ. 1.6 W @ 5 VDC

Mechanical

Lens mount
C-mount
Dimension (without lens)
35 mm × 35 mm × 8.6 mm (1.4" × 1.4" × 0.3")
Weight
Approx. 30 g (0.07 lb.)
Temperature
Working temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F)
Humidity
20% RH to 80% RH (no condensation)

General

Client software
MVS or third-party software with USB3 Vision Protocol
Operating system
32/64-bit Windows 7/10, 64-bit Windows 11, and 32/64-bit Linux
Compatibility
USB3 Vision, GenICam
Certification
CE, RoHS, KC

Firmware

Choosing a lens

Choosing a lens

Solve for
Focal length
16.8 mm
Magnification: 0.056×
Resolution per pixel
0.0408 mm/px
Smallest detectable feature: 0.123 mm

The formula holds for standard (entocentric) lenses and assumes the working distance is much larger than the focal length. It does not apply to telecentric lenses, and it accounts for neither depth of field nor distortion.

Lenses that fit this camera

Filtered by the C-mount thread and by coverage — the image circle is at least 7.05 mm, this sensor's diagonal. A smaller circle darkens the corners of every frame. Ask us to confirm

Data cables that fit